N5001 HACCP Auditor benefits
include: - > Provision of effective due diligence records
> Effective and efficient data capture relating to all aspects
of HACCP and Health and Safety, not just temperature
> Easy and efficient data analysis with reduced costs of processing
> Faster responses to identified problems
> Minimisation of human error
> Elimination of paper records
The N5001 has a large, backlit graphic display that can be
easily accessed from the keypad. This allows users to scroll through
option lists and can be set for right or left hand operation each
time the instrument is used - ideal for multi-user applications. The
instrument has an 8-pin Lumberg socket for secure temperature probe
attachment or for programming or downloading data via a PC. Other
facilities include: -
> Full security with authorised
users and pin numbers built into programming
> Robust case made from food safe ABS and dust and waterproof
to IP67 standards
> Exclusive range of type K and T thermocouple temperature probes
> Low running costs with over 500 hours use from one set of batteries
N5001 Auditor with BioCote® Protection
BioCote® is a silver based anti-microbial agent that is impregnated
into the instrument case during moulding. BioCote® effectively
inhibits the function, growth and reproduction of a wide range of
micro-organisms and its protection is increasingly accepted as part
of HACCP, due diligence and health and safety procedures. BioCote®
protection lasts for the life of the instrument, because the agent
is present throughout the case plastic and cannot rub off or be
washed or leached out.
BioCote® active ingredients are registered with the US Environmental
Protection Agency (EPA).
Although BioCote® inhibits the growth of micro-organisms on
the instrument case, it does not protect individuals against such
harmful organisms or remove the need to maintain the highest standards
of personal and product hygiene and cleanliness.
Specifications
PRODUCT
SPECIFICATION |
DESCRIPTION |
Sensor Type: |
Type K or T thermocouple |
Connector
|
Lumberg
8-pin |
Measurement
Range
Type K Type T
|
-200°C
to +700°C -328°F to +1292°F -200°C
to +400°C -328°F to +752°F |
Displayed
Resolution
|
0.1°C |
Instrument
Accuracy
|
<+/-0.2% of reading,
+/-0.2°C full ambient range |
Display
|
Full graphic display
LCD 128 x 64 pixels |
Operating
Range
|
-20°C to +50°C,
-4°F to +122°F |
Memory |
Approximately 3000
readings |
Upload Time
|
Typically 2 minutes
30 seconds for a 100K file |
Software |
Requires WindowsTM
2000 or XP |
Environmental
Protection : |
IP67, BS 60529, IEC
529 |
Case Material |
Food safe ABS |
Communications |
RS232 via Lumberg
8-pin connector |
Battery Type |
2 x 1.5V AA IEC LR6
Alkaline |
Battery Life |
Minimum of 500 hours
(backlight not used) |
Weight |
270g |
Dimensions
|
L 183mm x W 68/79mm
x D 31mm |
|