MGAprime H2
High end flue gas emission analyser for H2-analysis at industrial sites
- Precise and very stable offset measuring technique by means of non dispersive infrared (NDIR) technique, for enhanced long time measurements
- Up to 8 gas NDIR measurement: CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O/H2 and oxygen with O2-PM (paramagnetic cell)
- Remote control via smartphone or tablet using VCN server via LAN/WLAN (no remote control via MRU4u app)
- Wireless data transfer via Bluetooth dongle or WLAN dongle or via VNC server using LAN/WLAN
- Integrated, efficient dual heat exchanger gas cooler (Peltier type) with dual automatic condensate draining pumps
- Using single beam through sample cell for NDIR measurements
- Automatic zeroing by means of 3-way solenoid valve, internal sample flow volume measurement
- Strong, regulated sample gas pump and easy replaceable, effective PTFE filter
- Internal sample flow monitoring with display and alarm
- Zero gas (ambient air) air inlet nozzle and passive VENT outlet of sample gas (for use inside laboratories)
- O2 referencing (normalisation) to user settable value
- Large fuel type list incl. self choose fuels with user definable parameters
- Complete combustion calculation using country specific fuel type list
- Automatic internal test and control of soft- and hardware functions
- Automatic measurement incl. data logging function
- 7” high-resolution (800x480 pixel) TFT colour display with swipe and touch technique, with LINUX operating system
- Results stored in database - possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
- PC communication via LAN - Ethernet
- Data transfer to PC over LAN Ethernet (RJ45 socket) or USB
- Analog outputs (8-channels), analog inputs (4-channels)
- Modern and robust design, Aluminium enclosure with rubber molded impact protection for use in harsh industrial environment
H2 | 0...1.000ppm, Überlast bis 2.000ppm 0...10.000ppm, overload 20.000ppm |
O2 | (paramagnetic) 0 ... 25,00 % |
CO2 | (NDIR) 0 ... 50 % |
CO | (NDIR) 0...175 / 10.000 ppm |
HC (CH4) | (NDIR) 0 ... 500 / 10.000 ppm |
HC (C3H8) | (NDIR) 0 ... 200 / 5.000 ppm |
NO | (NDIR) 0 ... 200 / 4.000 ppm |
NO2 | (NDIR) 0 ... 150* / 1.000 ppm *only possible with optional acid dosage box |
SO2 | (NDIR) 0 ... 150* / 4.000 ppm *only possible with optional acid dosage box |
N2O | (NDIR) 0 ... 100 / 500 ppm |
Fluegas temperature | 0°C ... 1.200°C |
Ambient air temperature | 0°C ... 100 °C |
Differential pressure | -120 ... +120 hPa |
Flow Velocity | 3 ... 100 m/s |
Glas flow velocity and mass calculation by using a Pitot tube
H2S-measurement
0...500, overload up to 2.000 ppm
Range extension CO (NDIR) to 100.000 ppm