High end flue gas emission analyser for H2-analysis at industrial sites

  • Precise and very stable offset measuring technique by means of non dispersive infrared (NDIR) technique, for enhanced long time measurements
  • Up to 8 gas NDIR measurement: CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O/H2 and oxygen with O2-PM (paramagnetic cell)
  • Remote control via smartphone or tablet using VCN server via LAN/WLAN (no remote control via MRU4u app)
  • Wireless data transfer via Bluetooth dongle or WLAN dongle or via VNC server using LAN/WLAN
  • Integrated, efficient dual heat exchanger gas cooler (Peltier type) with dual automatic condensate draining pumps
  • Using single beam through sample cell for NDIR measurements
  • Automatic zeroing by means of 3-way solenoid valve, internal sample flow volume measurement
  • Strong, regulated sample gas pump and easy replaceable, effective PTFE filter
  • Internal sample flow monitoring with display and alarm
  • Zero gas (ambient air) air inlet nozzle and passive VENT outlet of sample gas (for use inside laboratories)
  • O2 referencing (normalisation) to user settable value
  • Large fuel type list incl. self choose fuels with user definable parameters
  • Complete combustion calculation using country specific fuel type list
  • Automatic internal test and control of soft- and hardware functions
  • Automatic measurement incl. data logging function
  • 7” high-resolution (800x480 pixel) TFT colour display with swipe and touch technique, with LINUX operating system
  • Results stored in database - possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
  • PC communication via LAN - Ethernet
  • Data transfer to PC over LAN Ethernet (RJ45 socket) or USB
  • Analog outputs (8-channels), analog inputs (4-channels)
  • Modern and robust design, Aluminium enclosure with rubber molded impact protection for use in harsh industrial environment
H20...1.000ppm, Überlast bis 2.000ppm 0...10.000ppm, overload 20.000ppm
O2(paramagnetic) 0 ... 25,00 %
CO2(NDIR) 0 ... 50 %
CO(NDIR) 0...175 / 10.000 ppm
HC (CH4)(NDIR) 0 ... 500 / 10.000 ppm
HC (C3H8)(NDIR) 0 ... 200 / 5.000 ppm
NO(NDIR) 0 ... 200 / 4.000 ppm
NO2(NDIR) 0 ... 150* / 1.000 ppm *only possible with optional acid dosage box
SO2(NDIR) 0 ... 150* / 4.000 ppm *only possible with optional acid dosage box
N2O(NDIR) 0 ... 100 / 500 ppm
Fluegas temperature0°C ... 1.200°C
Ambient air temperature0°C ... 100 °C
Differential pressure-120 ... +120 hPa
Flow Velocity3 ... 100 m/s

Glas flow velocity and mass calculation by using a Pitot tube

H2S-measurement

0...500, overload up to 2.000 ppm

Range extension CO (NDIR) to 100.000 ppm