NOVAplus "MCERTS"
Portable flue gas analyzer "MCERTS-certified"
- Complying with MCERTS performance standards for transportable emission monitoring systems
- Maximum flexibility through wireless remote control
NOVAplus MCERTS base unit:
- Robust metal enclosure mounted to an aluminium framed case
- Docking station for remote control with inductive charging function of RCU
- Built-in speedprinter
- Auto-zero solenoid valve for long-term measurementsand internal sample gas flow monitoring and alarm
- Peltier gas cooler with automatic condensate draining pump, with condensate monitoring and alarm
- Emission calculations like: : mg/m3, NOx as mg/m3 NO2, true measurement of NOx = NO + NO2, including O2 referencing (normalisation) to user settable value
- High energy lithium-ion battery and universal grid power supply 100-240Vac / 50-60 Hz, 12 Vdc, 60
- Industrial gas sampling probe using heated, easy replaceable quartz glass wool filter, with 2700 mm unheated Viton sample line and gas temperature measurement with K-type thermocouple (without exchangeable probe tubes)
NOVAplus MCERTS included remote control unit "Comfort":
- Wireless remote control of all instrument functions
- Backlit 3,5“TFT colour display
- Automatic measurement with data storage of measured values on SD card
- SD card (2 GB), mini USB port, internal memory for 16.000 data sets
- Contactless battery charging
- Lithium-ion battery with inductional charging, for approx. 30 hours mains free operation
- Differential pressure 0 ... +/- 100 mbar
- Gas flow velocity and mass flow measurement by using of Pitot tube (option)
O2 | 0 ... 25 % (electrochemical, long-life) |
CO (H2 compensated) | 0 ... 4.000 ppm* overload up to 10.000 ppm (electrochemical) |
CO low | 0...300ppm |
NO | 0...1.000 ppm |
NO low | 0...300ppm |
NO2 | 0 ... 200 ppm* overload up to 1.000 ppm (electrochemical) |
NO2 low | 0...300ppm (0,1ppm resolution) |
NO(x) | 0 ... 1.000 ppm* overload up to 5.000 ppm (electrochemical) |
SO2 | (option) 0 ... 2.000 ppm* overload up to 5.000 ppm (electrochemical) |
SO2 low | 0...300ppm (0,1ppm resolution) |
H2S | 0...500pm, Überlast < 2.000 ppm |
H2S low | 0...300ppm (0,1ppm resolution) |
CO2 | (option) 0 ... 20,00%* overload up to 40,00% (infrared) |
Differential pressure | at basic unit ± 100hPa, at remote control ± 200hPa |
External pressure sensor | up to 40 bar (option) |
Fluegas temperature | up to 1.100 °C (K-type thermocouple) |
Amount of leakage | 0 ... 8 l/h |
External temperature sensor | K-type standard |
Relative humidity | 3...98% |