Polytector
II G750
> 1 to 6 gases at a time
> CO2, toxic gases, combustibles, O2
> Automatic Calibration
> Smart sensors allow changing of measurement task
anytime
> Built in pump activated by pressing one button,
no pump adapter required
> Data logging
> Graphic display
> TWA/STEL
> Optional vibrating alarm
> Dimension: 90 x 199 x 60 (40) mm (WxHxD), 750 g
` II 2G EEx ib IIC T5
> UL Class I, Groups A, B, C, D
> Power supply: Rechargeable metal hydrid battery
pack
more... |
|
|
|
|
|
Polytector
III G850
> up to 7 gases
> toxic gases, combustibles, O2, ToxAlert Broad Range
Sensor
> alarm, 360° flashing LEDs, loud horn 99 dB
> Smart sensors allow changing of measurement task
anytime
> Built in pump, no pump adapter required
> Data logging, AutoCal, AutoZero
> Graphic display
> TWA/STEL
> Optional vibrating alarm
> small Dimension, 600 g
> Leak detection with external leak detection sensor
more... |
|
|
|
|
|
Microtector
G333
> 1 to 4 gases at a time
> Combustibles, O2, CO/H2S (Dualtox-Sensor)
> Power supply: Rechargeable metal hydrid battery
pack
> Single-button operation
> Long lifetime and reliability by fully protected electronics
> TWA/STEL, high/low peaks
> Zoom function to single reading
> Auto zeroing, AutoCal
> Ex-protection: ` II 2G EEx ib IIC T4
> 3 alarm levels
> Dimension: 60 x 133 x 33 mm (WxHxD), 385 g
> CENELEC and UL appoval and function test
more... |
|
|
|
|
|
CGM
II 900 (only available in USA, Singapore)
> 4 gas monitor plus ToxAlert (broad range sensor
for protection from hundreds of toxic gases)
> AutoCal
> Smart sensors allow changing of measurement task
anytime
> PTO (Power take off port) connection for mini pump
or data logger
> Graphic display
> TWA/STEL
> Dimension: 90 x 199 x 60 mm (WxHxD), 504 g
> UL 913 (classified intrinsically safe)
more... |
|
|
|
|
|
AGM
500 (only available in USA, Singapore)
> 2 to 4 gas monitor
> O2, combustible, two toxic gases (DUALTOX CO/H2S
available)
> AutoCal, AutoZero, LCD-Display
> Smart Instrument (Pre-programmed for all available
sensors)
> PTO (Power take off port) connection for mini pump
or data logger
> Calibration Time and date stamp
> TWA
> Dimension: 77,5 x 150 x 72,5 mm (WxHxD), 504 g
> UL Class I Division I C, D T3C
more... |
|
|
|
|
|
Iyoni
II
> 1 to 2 gas detector
> Gas detector integrated in a Willard cap lamp
> The unit includes sensor for CH4 (Methane) and CO
(Carbon Monoxide)
> Audible and visual alarm
> Dimension without lamp: 51 x 45 x 26 mm (WxHxD),
42 g
> Available in three versions: CO only, CH4 only or
CO + CH4 combined
> SABS IEC 79-0 Group I, 450°C (South Africa)
more... |
|
|
|
|