SWG 300 IND

Continuous Emission Monitoring System (Indoor)

  • Low sample flow extraction of only 50 l/h, to enhance the operation of sample gas preparation
  • Use of optimized NDIR technology with improved accuracy and without zero offset
  • O₂ measurement with a long-life electrochemical or a paramagnetic sensor
  • True NOx and SO₂ measurements through use of heated gas sampling probe and gas sampling line
  • Heated and temperature regulated acid mist catch & drain system for raw flue gas measurements with high acid aerosols
  • Complete heavy duty sample conditioning system for extractive cold and dry system
  • Ready to log, display and transfer data from dust concentra- tion monitor DM 401 and flow rate monitor DF 252.
  • IP54 steel cabinet 630 x 1.012 x 612 mm (W x H x D), with grey powder coating laquer, for wall mounting
  • With lockable acrylic front door and fan ventilation through the cabinet for use in clean ambient air
  • M&C Peltier gas cooler with dual heat exchanger with double automatic condensate draining pumps
  • Efficient sample gas filtration using PTFE sintered particulate filter
  • Condensate monitoring and alarm on display and gas sampling stop in case of alarm
  • Prepared for 10 % H3PO4 dosage in case of auto-cal or low SO₂/NO₂ measurements
  • Strong sample gas pump with sample gas flow monitoring and alarm
  • Filtration of acid gases to protect the internal sample gas flow sensor
  • Solenoid valve for auto-zero with clean ambient air
  • Solenoid valve for calibration gas, with aluminum fine pressure regulator at cal. gas inlet port
  • Main control unit 19" – 4U with human machine interface, prepared for measurement modules
  • Human machine interface with color TFT display, keyboard and standard RS485 interface (Modbus RTU)
  • Intuitive software guided menu, with diagnosis software and real-time data transfer
  • Power supply to analyser with 230 Vac / 47–63 Hz /200 W (add electric power for probe and heated sampling line)
  • Clean indoor mounting place, preferably air conditioned, cabinet has fan ventilation
  • Outdoor mounting in clean, +5 °C to 45 °C ambient, with mandatory sun & rain protection (user scope)
NO(infrared) 0 ... 200/4.000 ppm
NO2(infrared) 0 ... 150/1.000 ppm
SO2(infrared) 0 ... 150/4.000 ppm
CO2(infrared) 0 ... 50 %
CO(infrared) 0 ... 175/10.000 ppm
N2O(infrared) 0 ... 100/500ppm
CH4(infrared) 0 ... 500/10.000ppm
C3H8(infrared) 0 ... 200/5.000ppm
O2(electrochemical or paramagnetic) 0 ... 25 %
H2S(electrochemical) 0 ... 2.000/5.000ppm
H2(electrochemical) 0 ... 1.000/2.000ppm

6-gas NDIR module (CH4)

CO - CO2 - NO - NO2 - SO2 - CH4

6-gas NDIR module (C3H8)

CO - CO2 - NO - NO2 - SO2 - C3H8

8-gas NDIR module

CO - CO2 - NO - NO2 - N2O - SO2 - CH4 - C3H8

O2 (long-life) measurement

0...25%

O2 measurement, paramagnetic

0...25 %

H2S-measurement

0...500, overload up to 2.000 ppm

H2 - measurement

0...1.000,  overload up to 2.000 ppm

Gas sampling probe model HD-GW, for flue gas with soot, oily, acid mist

Gas sampling probe model HD, for flue gas with flying ash dust

I/O Module with 4chanel 4-20mA analog output and 2 alarm relays (fail-safe NO contacts)

RS 485 interface

with modbus RTU protocol for wired far distance data transfer

Alarm-Relais

4 alarm relays, potential-free contacts: 24 Vdc, 5 A

Phosphoric acid 10%

10 % H₃PO₄ dosage at low NOx and low SO₂

Anti-freezing heater

Anti-freezing heater with thermostat 230Vac/500W, for ambient temperature from -10°C

Automatic calibration

Automatic calibration by using of gas cylinders, calibration gas inlets, 200...500mbar

Heated acid separator

Heated acid separator with acid condensate pump

Downloads brochure

TechQuest_SWG-CEM

View

EN_Brochure_SWG300

View

EN-SWG300_IND_V1.0EN

View

SWG300_EU_Konformitaetserklaerung_DE_EN_20231121

View

SWG300_EU_Konformitaetserklaerung_DE_EN_20231121

View