Fields of application
The dust concentration measuring device PFM 97 W is used for the
continuous measurement of dust contents, especially for the emission
measurement according to TI Air, 13th, 17th and 27th BImSchV as
well as for the dust concentration measurement in process monitoring.
Parallel to the dust measurement flow and temperature of the smoke
gas are registered.
Function principle
The special probe of the PFM 97 consists of 2 tribo probes and
a dynamic pressure probe: The tribo probes register redundantly
the raw signal of the dust concentration. In order to correct
the velocity influence at the triboelectric measurement the gas
velocity is measured by means of a dynamic pressure probe. The
synchronous determination of the gas temperature allows the calculation
of the dust concentration in norm state. In case of high dust
contents the dynamic pressure probe of the PFM 97 can be cleaned
with the PCS 03.
|