Fields of application
The dust concentration measuring device PFM 97 W is used for the
continuous measurement of dust contents, especially for the emission
measurement according to TI Air, 13th, 17th and 27th BImSchV as
well as for the dust concentration measurement in process monitoring.
Parallel to the dust measurement flow and temperature of the smoke
gas are registered.
Function principle
The special probe of the PFM 97 consists of 2 tribo probes and a
dynamic pressure probe: The tribo probes register redundantly the
raw signal of the dust concentration. In order to correct the velocity
influence at the triboelectric measurement the gas velocity is measured
by means of a dynamic pressure probe. The synchronous determination
of the gas temperature allows the calculation of the dust concentration
in norm state. |