  Products > Dust - Opacity Monitors > Sub-Products > PFM 97 ED


Fields of application
The dust concentration measuring device PFM 97 ED is used for the continuous extractive measurement of dust contents in wet and sticky exhaust gases.
By means of a temperature-regulated probe the measuring gas is extracted from the process and led to the measuring chamber where the triboelectric dust sensors are placed.
In order to produce evaluable measuring signals and to protect the triboelectric measuring cell respectively the gas lines of the measuring device the measuring gas sucked off is continuously heated and diluted with dry and dust-free ambient air. The active principle of the dust measurement is based on the triboelectric effect. Therefore 2 electrically isolated half-shells are arranged in a cylindric chamber (measuring cell) and are passed by the conditioned measuring air. The triboelectric signals of the sensors are converted to equivalent dust signals in the electronic of the control unit.
STANDARD SCOPE OF DELIVERY TECHNICAL DATA
  • Special device consisting of probe and control unit.
  • Extractive dust measurement in wet and sticky gases (Measurement of a diluted and heated partial flow).
  • Assembly:
     - Control unit: wall    assembly or floor    mounting / frame
     - Probe: special flange    DN 80, PN 6, Di=100    mm
  • Analog outputs:
     - 4 ... 20 mA
  • Digital outputs (potential-free):
     - Limit value 1    (adjustable)
     - Limit value 2    (adjustable) /    Maintenance request
     - Failure
     - Maintenance
     - Measuring range    (automatic measuring    range change-over)
Control unit :
Steel-sheet case mounted on profile frame (incl. Gebläse)
Probe :
Extractive sampling with GRP weather protection hood
Measuring principle :

Dust: redundant measurement with 2 triboelectrich sensors

Measuring ranges :
Dust i.O.: 0 ... 15 (max. 500) mg/m³
Calibration : By gravimetric dust measurements
Display : 4-lines LCD-Display
Media temperature : max. 280 °C (higher temperatures on request)
Ambient temperature :
-20 ... +50 °C
Dew point difference:
min. +5 K
Flow velocity : independent
Analogue signals : 5 x 4 ... 20 mA, (including 2 x dust, temperature, flow) , galvanically isolated
Digital signals : 6 potential-free contacts (failure, maintenance, limit value 1 and 2 / maintenance request, measuring range)
Power supply : 400 VAC, 50 Hz, 3~
TÜV-approval : TI Air, 13th, 17th and 27th BImSchV