Home Contact Us   Catalogue Request  |  Dealer Enquiry
 SEARCH


delivering total solutions ..
..millenium technology
We, at Techmark, are committed for Customer Delight and not only Customer Satisfaction.

Products
Hand-Held Flue Gas Analysers
Portable Flue Gas Analysers
Continuous Emission Monitors (CEM's)
Dust / Opacity Monitors
Ambient Air Quality Monitoring Stations
Engine Exhaust Analysers
Gas Detectors
Efficiency Monitoring
Water Quality
Meteorology
Pressure & Flow Measurement : AIR
Pressure & Flow Measurement : LIQUID
Temperature Measurement
Samplers & Sample Preparation Equipment
Biogas-/ Syngas Analysis
Engine Exhaust Gas Analysis
Mercury Monitoring
Source / Stack Testing
Effluent Monitoring


  Products > Dust - Opacity Monitors > Sub-Products > PFM 97


Fields of application
The dust concentration measuring device PFM 97 is used for the continuous measurement of dust contents, especially for the emission measurement according to TI Air, 13th and 27th BImSchV as well as for the dust concentration measurement in process monitoring. Parallel to the dust measurement flow and temperature of the smoke gas are registered.

Function principle
The special probe of the PFM 97 consists of 2 tribo probes and a dynamic pressure probe: The tribo probes register redundantly the raw signal of the dust concentration. In order to correct the velocity influence at the triboelectric measurement the gas velocity is measured by means of a dynamic pressure probe. The synchronous determination of the gas temperature allows the calculation of the dust concentration in norm state.In case of high dust contents the dynamic pressure probe of the PFM 97 can be cleaned with the PCS 03.
STANDARD SCOPE OF DELIVERY TECHNICAL DATA
  • Basic device consisting of probe and control unit.
  • Combined device – measurement of dust, exhaust gas velocity or flow as well as temperature (option pressure) at the same time
  • Simple assembly:
     - Control unit: Wall    assembly
     - Probe: special flange    DN 80 PN 6, Di=100 mm
  • Analog outputs:
     - 4 ... 20 mA
  • Digital outputs (potential-free):
     - Limit value 1    (adjustable)
     - Limit value 2    (adjustable) /    Maintenance request
     - Failure
     - Maintenance
     - Measuring range    (automatic measuring    range change-over)
  • Display dust content in mg/m³ i.N.dr. possible
Control unit :
Weather-proof aluminium case, dimensions 305 x 240 x 300 mm (W x H x D), 3 kg, IP 65
Probe :
GRP weather protection hood, dimensions 300 x 400 x 1000 mm (W x H x D), ca. 10 kg
Measuring principle :

Dust: redundant measurement with 2 triboelectric probes; flow: differential pressure; temperature: Pt 100

Measuring ranges :
Temperature: 0 ... 300 °C, velocity: 0 ... 30 m/s flow: 0 ... 1.000.000 m³/h, dust i.O.: 0 ... 20 (max. 500) mg/m³, Dust i.N.: 0 ... 20/45/150/500 mg/m³
Calibration : By gravimetric dust measurements
Display : 4-lines LCD-Display
Media temperature : max. 280 °C (higher temperatures on request)
Ambient temperature :
-20 ... +50 °C
Dew point difference:
min. +5 K
Flow velocity : From appr. 3 m/s
Analogue signals : 5 x 4 ... 20 mA, (including 2 x dust, temperature, flow) , galvanically isolated
Digital signals : 6 potential-free contacts (failure, maintenance, limit value 1 and 2 / maintenance request, measuring range)
Power supply : 110 VAC, 230 VAC or 24 VDC
TÜV-approval : TI Air, 13th and 27th BImSchV