Application and function
The mobile filter controller PFM 92 K is a perfect device in order
to determine effectively damages at filtering precipitators (e.g.
defective filter bags, inactive membrane valves, insufficient filter
element fixings, not tightly-closing poppet valves…). The filter
diagnosis unit PFM 92 K serves the qualitative monitoring of dusty
emissions. In particular it is often used for the quick registration
of the clean gas dust content behind de-dusting facilities. The measuring
principle is based on the use of the triboelectric effect (charge
transfer at colliding or passing of particles on leading surfaces).The
filter controller consists of an isolated probe which is installed
in the clean gas channel. The charge transferred by contact and triboelectric
processes is derived as current, converted in the evaluation unit,
amplified and provided as norm signal 4 ... 20 mA. The measuring values
resp. the filter diagram can be seen and evaluated immediately via
the integrated electronic recorder
Specifications
PRODUCT
SPECIFICATION |
DESCRIPTION |
Control unit: |
Portable aluminium
suit-case, 370 x 490 x 215 mm (H x W x D), IP 20 |
Probe: |
Stainless-steel probe
rod with pre-amplifier in the probe head, probe length:
30 ... 500 mm (adjustments possible), IP 65 |
Measuring principle: |
Dust: measurement
with 1 triboelectric sensor |
Measuring range: |
0,1 ... 1.000 mg/m³
(special measuring ranges on demand) |
Calibration: |
By gravimetric reference
measurements |
Display: |
LCD-Display (0 ...
100 %) resp. recorder |
Media temperature: |
max. 280 °C |
Ambient temperature: |
-20 ... +50 °C
|
Dew point
difference: |
min. +5 K |
Flow velocity: |
From appr. 3 m/s |
Analogue signals: |
1 x 4 ... 20 mA (dust)
|
Analogue inputs: |
Optionally max. 2
x 4 ... 20 mA |
Power supply: |
230 VAC (optionally
accumulator operation) |
TÜV-Approval: |
TI-Air |
|