Home Contact Us   Catalogue Request  |  Dealer Enquiry
 SEARCH


delivering total solutions ..
..millenium technology
We, at Techmark, are committed for Customer Delight and not only Customer Satisfaction.

Products
Hand-Held Flue Gas Analysers
Portable Flue Gas Analysers
Continuous Emission Monitors (CEM's)
Dust / Opacity Monitors
Ambient Air Quality Monitoring Stations
Engine Exhaust Analysers
Gas Detectors
Efficiency Monitoring
Water Quality
Meteorology
Pressure & Flow Measurement : AIR
Pressure & Flow Measurement : LIQUID
Temperature Measurement
Samplers & Sample Preparation Equipment
Biogas-/ Syngas Analysis
Engine Exhaust Gas Analysis
Mercury Monitoring
Source / Stack Testing
Effluent Monitoring


  Products > Dust - Opacity Monitors > Sub-Products > PFM 92 Ex


Features
 > Ex-version of the basic device consisting of     probe and control unit
 > Application in
    - Probe: Ex II 1D
    - Probe head: Ex II 3D
    - Control unit: non-ex-area
 > Simple assembly:
    - Control unit: wall assembly
    - Probe: 1"-sleeve (DIN 2986) optionally       flange DN 25 PN 6
 > Analog output:
    - Dust: 4 ... 20 mA
 > Digital outputs (potential-free):
    - Limit values 1 and 2 (adjustable)
    - Error (power failure)
 > 4 measuring ranges adjustable:
 > In relation 0,33 : 1 : 3,33 : 10
 > Application in zone 20 (probe) and zone 22     (probe head)
 > Control unit: non-Ex-area
Application and function

The filter controller PFM 92 Ex serves the qualitative monitoring of dusty emissions in areas endangered by dust explosions. In particular it is often used for the registration of the clean gas dust content behind de-dusting facilities. The measuring principle is based on the use of the triboelectric effect (charge transfer at colliding or passing of particles on leading surfaces).

The filter controller consists of an isolated probe which is installed in the clean gas channel. The charge transferred by contact and triboelectric processes is derived as current, converted in the evaluation unit, amplified and provided as norm signal 4 ... 20 mA. Via a limit value detector the exceeding of the allowable emission limit value can be signalised optically or acoustically.


Specifications

 PRODUCT SPECIFICATION  DESCRIPTION
 Control unit:  Weather-proof aluminium case IP 65,  Dimensions: 210 x 240 x 280 mm (H x W x  D)
 Probe:  Stainless steel probe rod with pre-amplifier  in the probe head, probe length 300 mm  (adjustments possible), IP 65
 Measuring principle:  Dust: measurement with 1 triboelectric  sensor
 Measuring range:  0,1 ... 1.000 mg/m³ (special measuring  ranges on demand)
 Calibration:  By gravimetric reference measurements
 Display:  LCD-Display (0 ... 100 %)
 Media temperature:  max. 280 °C
 Ambient temperature:  -20 ... +50 °C
 Dew point difference:  min. +5 K
 Flow velocity:  From appr. 3 m/s
 Analogue signals:  1 x 4 ... 20 mA (dust)
 Digital signals:  3 potential-free contacts (failure, limit value  1 and 2)
 Power supply:  230 VAC
 ATEX-Guideline:  Probe: Ex II 1D zone 22, probe head: Ex II  3D, control unit: not-Ex-area
 TÜV-Approval:  TI-Air