  Products > Ambient Air Quality Monitors Stations (AAQMS) > Sub Products > Ambient NOx Monitor

Features
 
The APNA-370 uses a combination of the dual cross flow modulation type chemiluminescence principle and the referential calculation method.
This gives it the advantages of the single-detector method plus the ability to do continuous measurements of NOx, NO, and NO2. The design gives great stability and extremely high sensitivity (0.1 ppm F.S.)

Standard equipment includes a drier unit with an automatic recycle function to provide dry ambient air as the ozone source. This makes long-term continuous measurements possible.
The detector uses a silicon photodiode sensor to reduce size and prolong working life.

All the necessary features are built right into a single rack-sized unit, including a reference-gas generator, an ozone-source drier unit, an ozone decomposer, and a sampling pump. No supplemental gas is required.

Principles

Cross flow modulation type, reduced pressure chemiluminescence (CLD)
The chemiluminescence method uses the reaction of NO with O3
NO+O3 → NO2*+O2
NO2+NO2+h ν
A portion of the NO2 generated as the result of this reaction becomes NO2*. As these excited molecules return to the ground state, chemiluminescence is generated in the range of 600 nm to 3,000 nm. The light intensity is in proportion to the concentration of NO molecules and by measuring it we obtain the NO concentration of the sample. A deoxidation conver-ter changes the NO2 to NO, which is measured. In other words, the NO2 concentration can be obtained by the difference between (1) the NOx concentration measured when the sample gas is directed through a converter and (2) the NO concentration measured when the gas is not run through the converter.


Specifications
 PRODUCT SPECIFICATION  DESCRIPTION
 Principle:  Cross flow modulation type, reduced  pressure chemiluminescence (CLD)
 Application:  NO2, NO and NOx in ambient air
 Range:
 Standard ranges: 0-0.1/0.2/0.5/1.0 ppm;  auto range ~ manual range selectable;
 can be operated by remote switching.
 Optional (measurable) ranges: 4 ranges  selectable from 0-10 ppm, within 10 times  range ratio;
 auto range ~ manual range selectable; can  be operated by remote switching.
 Repeatability:
 ±1.0% F.S.
 Linearity:  ±1.0% F.S
 Sample gas flow rate:  Approx. 0.8L/min
 Indication:  Measured value, range, alarm,  maintenance screen
 Alarms:  During AIC, zero calibration error, span  calibration error, temperature error in  converter, etc.
 On-screen messages are  available in four  languages:  English, German, French, and Japanese.
 Input/output:  • 0-1 V/0-10 V/4-20 mA, to be specified (2  systems: either (1) momentary value and  integrated or (2) moving average value)
 • Contact input/output
 • RS-232C
 Power:  100/110/115/120/220/230/240 VAC, 50/60  Hz (to be specified)
 Dimensions:  430(W) x 550(D) x 221(H) mm
 Mass:  Approx. 21 kg

Dimension Outline