Features
> One piece of equipment makes possible simultaneous
and continuous measurements of the concentrations
of the two components, total nitrogen and total phosphorus. (PN-1000).
> By using an ultraviolet ray oxidizing analysis
method unique to us, we made great cuts in maintenance
operations without losing high correlation with the previously used
autoclave method.
> With
the ultraviolet ray oxidizing analysis method, prehandling at low
temperatures (under 100 degrees C) and at
normal pressure is possible so that, compared to the previously used
autoclave method, ease of maintenance is vastly improved and fewer
parts need to be replaced.
> In
all series, there is a high correlation with the previously used manual
analysis method, and it is possible to answer
the need for continuity of data. The amount of test chemicals used
is one-third of that of previous models. Low running costs have been
achieved.
- Filled with
a wide variety of functions that stress ease of use
- Automatic zero
point adjustments (for each measurement)
- Automatic correction
function (can set frequency of correction)
- Self-diagnosis
function (prints out abnormal content and outputs it)
- External control
function
- Data memory
function (for two weeks)
- Conversion
to manual analysis with primary formula (using correlation formula
for manual
analysis, can convert to manual analysis values)
Applications
> Automatic analysis of total nitrogen and total phosphorus
in drain water
> Automatic analysis of total nitrogen and total phosphorus
during processing to remove nitrogen
> Automatic analysis of total nitrogen and total phosphorus
in ocean areas, lakes, marshes and rivers
> Automatic analysis of total nitrogen and total phosphorus
during manufacturing processes (of fertilizers,
pharmaceuticals, etc.)
> Automatic analysis of total phosphorus during processing
to remove phosphorus
Specifications
PRODUCT
SPECIFICATION |
DESCRIPTION |
Measurement principle: |
PA ~ 1000: alkali
peroxomonosulfuric acid potassium/ ultraviolet oxidation
decomposition ~ ultraviolet absorption methods;
peroxomonosulfuric acid potassium/ ultraviolet oxidation
decomposition ~ ultraviolet absorption methods |
Measurement
range: |
Total nitrogen:
0mgN/l-2 mgN/l (standard range), 0mgN/l- 50mgN/l
(one-step dilution method), 0mgN/l-1,000mgN/l (two-step
dilution method), optional settings available within
every range; Total phosphorus: 0mgP/l-0.5mgP/l
(standard range), 0mgP/l- 10mgP/l (one-step dilution
method), 0mgP/l -250mgP/l (two-step dilution method),
optional settings available within every range. |
|